Skip to main content
20 events
when toggle format what by license comment
Jun 17, 2020 at 8:51 history edited CommunityBot
Commonmark migration
Mar 6, 2020 at 9:07 comment added Yogesh Bangar Please share the VPC configuration of 3K and 9K
Jan 11, 2019 at 11:35 comment added Marc 'netztier' Luethi You may also want to check if lacp suspend-individual is active on port-channel interfaces by default on that switch. I found it to be active by default on N3K-3164Q-40GE with 7.0(3)I4(6). This gave the server guys a hard time bootstrapping their server, because the bonding driver isn't running during all phases of the setup (or boot) phase, and the port remained suspended. I had to turn it off for all port-channel objects (no lacp suspend-individual) to allow the ports to come up. Note that this might be a bad idea for inter switch links, but for edge ports to servers it is acceptable.
Jan 11, 2019 at 11:20 answer added screenie timeline score: 0
Nov 10, 2018 at 18:00 history tweeted twitter.com/StackNetworkEng/status/1061317692169297921
Nov 9, 2018 at 16:57 vote accept Satish
Nov 6, 2018 at 22:00 history bumped CommunityBot This question has answers that may be good or bad; the system has marked it active so that they can be reviewed.
Oct 7, 2018 at 21:00 history bumped CommunityBot This question has answers that may be good or bad; the system has marked it active so that they can be reviewed.
Sep 7, 2018 at 20:00 history bumped CommunityBot This question has answers that may be good or bad; the system has marked it active so that they can be reviewed.
Aug 8, 2018 at 19:00 history bumped CommunityBot This question has answers that may be good or bad; the system has marked it active so that they can be reviewed.
Jul 9, 2018 at 18:47 answer added Satish timeline score: 2
Jul 9, 2018 at 17:42 comment added Satish frustrated now, look like its not VLAN issue, i did same thing on other server and it didn't work :( still digging
Jul 9, 2018 at 17:06 comment added Satish I found issue, on switch side i have configured switchport trunk allowed vlan 10,20,30 but on server side i only configured VLAN 10,20 it was the issue, look like LACP negotiating VLAN also, How to stop VLAN negotiation on LACP, reason we set multiple VLAN on trunk so it will allow us to setup server dynamically and we don't need to go to every switch and adjust VLAN, Anyone know how to make it work?
Jul 9, 2018 at 15:41 comment added Satish @Zac67 I have updated output of linux side boding its saying Dynamic link aggregation so does that means auto right? as soon as i set channel-group 1 mode on it brought up vpc but server not pinging
Jul 9, 2018 at 15:39 history edited Satish CC BY-SA 4.0
added 712 characters in body
Jul 9, 2018 at 15:28 comment added Zac67 Make sure you've got active LACP configured on at least one side - a passive-passive LACP trunk won't come up (but should as a single interface).
Jul 9, 2018 at 14:48 history edited Satish CC BY-SA 4.0
added 1609 characters in body
Jul 9, 2018 at 12:25 comment added Satish In logs i am not seeing anything interesting, all standard logs IF up IF down, should i need to increase logging, if you then do you know what logging level i need to set?, i will try to remove bpduguard and try will update you result soon
Jul 9, 2018 at 6:26 comment added Zac67 What does the log show when the vPC is first brought up/the server is booted? My guess is there's a BPDU from the server and the bpduguard option shuts the bond.
Jul 9, 2018 at 5:05 history asked Satish CC BY-SA 4.0