Skip to main content
6 events
when toggle format what by license comment
Nov 4, 2018 at 8:51 vote accept Shyamkkhadka
Sep 3, 2018 at 16:40 comment added Ron Maupin There is some other problem, and disabling STP is a dangerous way to get around the problem. If you would simply edit your question to include what people has asked, then we could try to help you determine the root of the problem and solve it correctly.
Sep 3, 2018 at 15:29 comment added Shyamkkhadka There was not multiple connections between two switches, only single link was there. But as you said there may be problem with the BPDU guard configuration.
Sep 3, 2018 at 15:17 comment added Zac67 You haven't told us anything about multiple connections between both switches - how are we supposed to solve your problem? Generally, multiple connections between switches are blocked (=need to be blocked) by STP to prevent bridge loops. Alternatively, multiple links between two switches can be aggregated (LAG). If there are only single links between the switches you've got a problem with the BDPU guard configuration or similar. Deactivating STP is not a good idea generally.
Sep 3, 2018 at 6:59 history edited Shyamkkhadka CC BY-SA 4.0
deleted 52 characters in body
Sep 3, 2018 at 6:51 history answered Shyamkkhadka CC BY-SA 4.0