This is my first post into Cisco Forum, however I'm used to check it for every question or problem I have.
I'm putting back in production a Cisco 4507R-E switch with two supervisors, and what I need si to enable all SFP ports of 1Gbit by giving up the four ten gigabit ports, which I don't need anymore for the new purpose.
I've read that to accomplish that i need to issue the next command on the global config
hw-module uplink select gigabitethernet
But the switch do no recognise the command:
MAT_SW1_PT2(config)#hw-module ?
module Specify a linecard slot for the hw-module command
slot Specify a linecard slot for the hw-module command
MAT_SW1_PT2(config)#hw-module
Here is my running-config:
MAT_SW1_PT2#sh module
Chassis Type : WS-C4507R-E
Power consumed by backplane : 40 Watts
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 48 10/100/1000BaseT (RJ45)V, Cisco/IEEE WS-X4548-GB-RJ45V JAE14041TI2
2 48 10/100/1000BaseT (RJ45)V, Cisco/IEEE WS-X4548-GB-RJ45V JAE14041TDM
3 6 Sup II+10GE 10GE (X2), 1000BaseX (SFP) WS-X4013+10GE JAE1345NFR6
4 6 Sup II+10GE 10GE (X2), 1000BaseX (SFP) WS-X4013+10GE JAE1342LA4P
5 48 10/100/1000BaseT (RJ45)V, Cisco/IEEE WS-X4548-GB-RJ45V JAE14041TH1
6 48 10/100/1000BaseT (RJ45)V, Cisco/IEEE WS-X4548-GB-RJ45V JAE14310J4A
7 48 10/100/1000BaseT (RJ45)V, Cisco/IEEE WS-X4548-GB-RJ45V JAE151702VS
M MAC addresses Hw Fw Sw Status
--+--------------------------------+---+------------+----------------+---------
1 8843.e16c.6410 to 8843.e16c.643f 4.1 Ok
2 8843.e16c.5ff0 to 8843.e16c.601f 4.1 Ok
3 8843.e141.6740 to 8843.e141.6745 1.8 12.2(31r)SGA 12.2(31)SGA8 Ok
4 8843.e141.6746 to 8843.e141.674b 1.8 12.2(31r)SGA 12.2(31)SGA8 Ok
5 8843.e16a.a9e0 to 8843.e16a.aa0f 4.1 Ok
6 d0d0.fd3c.80c0 to d0d0.fd3c.80ef 5.0 Ok
7 e05f.b9d0.40e0 to e05f.b9d0.410f 5.1 Ok
Mod Redundancy role Operating mode Redundancy status
----+-------------------+-------------------+----------------------------------
3 Active Supervisor SSO Active
4 Standby Supervisor SSO Standby hot
MAT_SW1_PT2#sh running-config
....
redundancy
main-cpu
auto-sync standard
mode sso
no file verify auto
....
MAT_SW1_PT2#sh ver
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500-IPBASE-M), Version 12.2(31)SGA8, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2008 by Cisco Systems, Inc.
Compiled Tue 29-Jul-08 12:23 by tinhuang
Image text-base: 0x10000000, data-base: 0x114B25F4
ROM: 12.2(31r)SGA4
Pod Revision 16, Force Revision 34, Tie Revision 32
Any ideas?? Could be due old firmware?
Thanks in advance!!
TenGigabit
rather thanGigabit
. We use a lot of 4507R+E with Supervisor 7, and we just use the proper optics for the situation, but do not use any different configuration commands (other than QoS).