Can I access the software modul of sourcefire with ip address from my inside ip subnet over the inside physical port? And to use management ports only for managing ASAs.
1 Answer
Not without some modification, you need to put a cable between one of your local ports to the management port, we Always use port GigabitEthernet1/8(ASA5506)
interface GigabitEthernet1/8
nameif Firewizz-Management
security-level 100
zone-member MANAGEMENT
ip address 10.203.7.250 255.255.255.0
!
interface Management1/1
management-only
nameif management
security-level 0
no ip address
!
object network obj_PAT_FirePower_Management_From_WAN
nat (Firewizz-Management,WAN) static interface service tcp https 8443
sourcefire:
> show network
===============[ System Information ]===============
Hostname : XXXX.LOCAL
DNS Servers : 10.203.7.250
Management port : 8443
IPv4 Default route
Gateway : 10.203.7.250
======================[ eth0 ]======================
State : Enabled
Channels : Management & Events
Mode :
MDI/MDIX : Auto/MDIX
MTU : 1500
MAC Address : 54:A2:74:27:90:B8
----------------------[ IPv4 ]----------------------
Configuration : Manual
Address : 10.203.7.251
Netmask : 255.255.255.0
Broadcast : 10.203.7.255
----------------------[ IPv6 ]----------------------
Configuration : Disabled
===============[ Proxy Information ]================
State : Disabled
Authentication : Disabled
Hope it helped ;) If you cant get it working say what is't and ill get back on it.